  1.                          SECTION 02621
  2.  
  3.                    FOUNDATION DRAINAGE PIPING
  4. NOTE ** This section is based on the Form-A-Drain system
  5.         products manufactured by CertainTeed Corporation,
  6.         Pipe and Plastics Group, at the following address:
  7. NOTE **      750 E. Swedesford Road
  8. NOTE **      P.O. Box 860
  9. NOTE **      Valley Forge PA 19482
  10. NOTE **      Voice (610) 341-6950
  11. NOTE **      FAX   (610) 341-6837
  12. NOTE **
  13. NOTE ** Installing the Form-A-Drain system by CertainTeed
  14.         offers a solution to three construction
  15.         requirements at once; the Form-A-Drain system
  16.         functions as:
  17. NOTE **
  18. NOTE **      Formwork for footings.
  19. NOTE **      Foundation drainage system.
  20. NOTE **      Radon gas evacuation system.
  21. NOTE **
  22. NOTE ** The Form-A-Drain system conforms to "Model
  23.         Standards and Techniques for Control of Radon in
  24.         New Residential Buildings" - Environmental
  25.         Protection Agency (EPA), and is the subject of BOCA
  26.         Research Report Number 95-37, dated 1995.
  27. NOTE **
  28. NOTE ** SECTION 02621 - FOUNDATION DRAINAGE PIPING,
  29.         Copyright 1997, The Architect's Catalog, Inc.
  30.  
  31.  
  32. PART 1  GENERAL
  33.  
  34. 1.1 SECTION INCLUDES
  35. NOTE ** Delete items below not required for project.
  36.  
  37.     A.  Foundation Drainage System.
  38.  
  39.     B.  Perimeter Radon Gas Evacuation System.
  40.  
  41. 1.2 RELATED SECTIONS
  42. NOTE ** Delete any sections below not relevant to this
  43.         project; add others as required.
  44.  
  45.     A.  Section 02300 - Earthwork.
  46.  
  47.     B.  Section 03300 - Cast-In-Place Concrete.
  48.  
  49. 1.3 REFERENCES
  50. NOTE ** Delete references from the list below that are not
  51.         actually required by the text of the edited
  52.         section.
  53.  
  54.     A.  ASTM D 2729 - Standard Specification for Poly(Vinyl
  55.         Chloride) (PVC) Sewer Pipe and Fittings.
  56.  
  57.     B.  ASTM E 1465 - Standard Guide for Radon Control Options
  58.         for the Design and Construction of New Low-Rise
  59.         Residential Buildings.
  60.  
  61.     C.  ASTM F 405 - Standard Specification for Corrugated
  62.         Polyethylene (PE) Tubing and Fittings.
  63.  
  64.     D.  ASTM F 891 - Standard Specification for Coetruded
  65.         Poly(Vinyl Chloride) (PVC) Plastic Pipe with a Cellular
  66.         Core.
  67.  
  68.     E.  EPA 402R94009 - Model Standards and Techniques for
  69.         Control of Radon in New Buildings; Environmental
  70.         Protection Agency.
  71.  
  72. 1.4 SUBMITTALS
  73.  
  74.     A.  Submit under provisions of Section 01300.
  75.  
  76.     B.  Product Data:  Manufacturer's descriptive literature for
  77.         system, including all components.
  78.  
  79.     C.  Shop Drawings:  Indicate layout of system; include all
  80.         components specified in manufacturer's descriptive
  81.         literature or installation instructions, and components
  82.         indicated in contract documents.
  83.  
  84.     D.  Manufacturer's Instructions:  Printed installation
  85.         instructions for system, including each component
  86.         indicated in shop drawings.
  87. NOTE ** Delete the following Article if radon evacuation
  88.         system is not required.
  89.  
  90. 1.5 QUALITY ASSURANCE
  91.  
  92.     A.  Perimeter Radon Evacuation System:  Provide products that
  93.         can be assembled into system that meets requirements of:
  94.         1.  ASTM E 1465.
  95.         2.  EPA 402R94009.
  96.         3.  Provide test reports from independent testing
  97.             laboratory supporting compliance.
  98.  
  99. PART 2  PRODUCTS
  100.  
  101. 2.1 MANUFACTURERS
  102.  
  103.     A.  Acceptable Manufacturer:  Certainteed Corporation, Pipe
  104.         and Plastics Group; 750 E. Swedesford Road, P.O. Box 860,
  105.         Valley Forge PA 19482. ASD. Tel: (610) 341-6950, Fax:
  106.         (610) 341-6837.
  107. NOTE ** Delete one of the two following paragraphs;
  108.         coordinate with Division 01 requirements.
  109.  
  110.     B.  Requests for substitutions will be considered in
  111.         accordance with provisions of Section 01600.
  112.  
  113.     C.  Substitutions:  Not permitted.
  114.  
  115.     D.  Unless otherwise specified for an individual product or
  116.         material, supply all products specified in this section
  117.         from the same manufacturer.
  118.  
  119. 2.2 COMPONENTS
  120.  
  121.     A.  Linear Components:  Polyvinyl chloride (PVC) containing
  122.         post-consumer recycled plastic materials, extruded in
  123.         closed-channel cross-section, with slot perforations
  124.         along length to permit moisture migration, 12-foot (3.65
  125.         m) lengths.
  126.         1.  Load Deflection and Impact Resistance:  Comply with
  127.             requirements of ASTM F 891 for Type PS 25 PVC pipe.
  128.         2.  Flow Characteristics:  Meet or exceed the flow
  129.             characteristics of 4 inch (100 mm) diameter
  130.             corrugated polyethylene slotted pipe conforming to
  131.             ASTM F 405, when subjected to 30-7/8 inch (770 mm)
  132.             pressure head.
  133.         3.  Type:  Form-A-Drain Part LN124, size 2-1/4 inches (57
  134.             mm) wide by 4 inches (100 mm) deep, single-channel.
  135.         4.  Type:  Form-A-Drain Part LN126, size 2-1/4 inches (57
  136.             mm) wide by 6 inches (152 mm) deep, dual-channel.
  137.         5.  Type:  Form-A-Drain Part LN128, size 2-1/4 inches (57
  138.             mm) wide by 8 inches (203 mm) deep, dual-channel.
  139.  
  140.     B.  Fittings:
  141.         1.  Material:  Same as linear components, extruded or
  142.             molded in profiles and shapes as follows:
  143. NOTE ** Delete one or more of the following sub-paragraphs
  144.         which specify products not required for project.
  145.             a.  Coupling:  Form-A-Drain Part XCPLx.
  146.             b.  Coupling with hole:  Form-A-Drain Part COUPx.
  147.             c.  90-degree corner coupling:  Form-A-Drain Part
  148.                 CN90x.
  149.             d.  45-degree corner coupling:  Form-A-Drain Part
  150.                 CN45x.
  151.             e.  Outlet, 4 inch diameter stub:  Form-A-Drain Part
  152.                 OUT4x.
  153.             f.  Double outlet, 4 inch diameter stubs:  Form-A-
  154.                 Drain Part DOF4x.
  155.             g.  90-degree vertical "L":  Form-A-Drain Part VL90x.
  156.             h.  90-degree vertical "T":  Form-A-Drain Part VTEEx.
  157.         2.  Size:  As required for linear components specified,
  158.             indicated as final lower-case "x" in specified
  159.             fitting part numbers (4, 6, or 8 inches).
  160.  
  161.     C.  Accessories:
  162. NOTE ** System components are fastened to grade stakes at
  163.         specified intervals to set top of system to
  164.         indicated top-of-footing elevations and maintain
  165.         system level, so system can function as formwork;
  166.         grade stakes can remain after footings are poured.
  167. NOTE **
  168. NOTE ** Retain the following sub-paragraphs which specify
  169.         products required for project.
  170.         1.  Grade stake:  Form-A-Drain Part GS018, length 18
  171.             inches (457 mm).
  172.         2.  Grade stake:  Form-A-Drain Part GS030, length 30
  173.             inches (762 mm).
  174. NOTE ** Spacer straps are placed between inner system and
  175.         outer system at specified intervals to maintain
  176.         constant width of footing footprint; spacer straps
  177.         are cast into footings as poured.
  178. NOTE **
  179. NOTE ** Retain the following sub-paragraphs which specify
  180.         products required for project.
  181.         3.  Spacer strap:  Form-A-Drain Part SS416, width 16
  182.             inches (406 mm).
  183.         4.  Spacer strap:  Form-A-Drain Part SS420, width 20
  184.             inches (510 mm).
  185.         5.  Spacer strap:  Form-A-Drain Part SS424, width 24
  186.             inches (610 mm).
  187. NOTE ** Cross-over pipes are placed at locations where
  188.         inner and outer systems are required to be
  189.         connected; cross-over pipes are cast into footings
  190.         as poured.
  191. NOTE **
  192. NOTE ** Retain the following sub-paragraphs which specify
  193.         products required for project.
  194.         6.  Cross-over pipe:  Form-A-Drain Part CP216, 2 inches
  195.             (50 mm) diameter, length 16 inches (406 mm).
  196.         7.  Cross-over pipe:  Form-A-Drain Part CP220, 2 inches
  197.             (50 mm) diameter, length 20 inches (510 mm).
  198.         8.  Cross-over pipe:  Form-A-Drain Part CP224, 2 inches
  199.             (50 mm) diameter, length 24 inches (610 mm).
  200. NOTE ** Retain the following sub-paragraphs which specify
  201.         products required for project.
  202.         9.  Fasteners:  Steel drill screws of length specified in
  203.             manufacturer's installation instructions.
  204.         10. Reinforcing bar:  Deformed steel of diameter
  205.             specified in manufacturer's installation
  206.             instructions.
  207.  
  208.     D.  Piping Connecting Foundation Drains to Outlets:  PVC,
  209.         ASTM D 2729, of diameter required.
  210.  
  211.  
  212. PART 3  EXECUTION
  213.  
  214. 3.1 INSTALLATION
  215.  
  216.     A.  Lay out system to footing footprint indicated on
  217.         drawings; locate fittings in accordance with
  218.         manufacturer's instructions and as indicated.
  219.  
  220.     B.  Maintain indicated footing widths by installing spacer
  221.         straps; locate in accordance with manufacturer's
  222.         instructions and as indicated.
  223.  
  224.     C.  Raise top of system to indicated top-of-footing
  225.         elevations, using reinforcing bars driven through holes
  226.         in corner couplings into soil; maintain elevations by
  227.         using grade stakes, located in accordance with
  228.         manufacturer's instructions and as indicated, driven into
  229.         soil and screw-fastened to system.
  230.  
  231.     D.  Ensure that all required and indicated components are in
  232.         place, and system is level at indicated top-of-footing
  233.         elevations, before beginning installation of cast-in-
  234.         place concrete footings.
  235.  
  236.     E.  Installation of cast-in-place concrete footings is
  237.         specified in Section 03300.
  238.  
  239.     F.  Connect drainage piping to system as indicated before
  240.         placement of stone fill, specified in Section 02300.
  241.  
  242.  
  243.                          END OF SECTION
  244.